Please use this identifier to cite or link to this item: http://hdl.handle.net/2440/119382
Citations
Scopus Web of Science® Altmetric
?
?
Full metadata record
DC FieldValueLanguage
dc.contributor.authorTanwar, A.S.en
dc.contributor.authorPatidar, S.en
dc.contributor.authorAhirwar, S.en
dc.contributor.authorDehingia, S.en
dc.contributor.authorIyer, P.K.en
dc.date.issued2019en
dc.identifier.citationThe Analyst, 2019; 144(2):669-676en
dc.identifier.issn0003-2654en
dc.identifier.issn1364-5528en
dc.identifier.urihttp://hdl.handle.net/2440/119382-
dc.description.abstractTwo "receptor-free" blue fluorescent conjugated polymers (CPs) of fluorene namely 9,9-bis(6-bromohexyl)-2-phenyl-9H-fluorene (PF1) and 9,9-bis(6-bromohexyl)-9H-fluorene (PF2) were synthesized using Suzuki cross coupling polymerization and oxidative coupling polymerization methods in high yields and well characterized by gel permeable chromatography, NMR, UV-vis, fluorescence and time-resolved photoluminescence (TRPL) spectroscopy. Both CPs explicitly recognized nitroexplosive picric acid (PA) and displayed a fluorescence quenching response in solution and on a solid support via the Inner Filter Effect (IFE) mechanism. Both CPs were highly selective and sensitive towards PA with high quenching constant values (Ksv) of 5.1 × 104 M-1 and 5.0 × 104 M-1 and remarkably low limit of detection (LOD) values of 110 nM and 219 nM. Contact mode detection of PA was also accomplished using economical and transportable fluorescent paper test strip devices for on-site sensing, which detect a minimum of 22.9 femtograms of PA. The IFE mechanism for PA sensing (or for other analytes) is an interesting concept that can detect PA by just having blue fluorescence. Therefore, careful experiments for IFE correction were performed herein for PA detection to observe ∼77% suppression efficiency due to the IFE. These studies provide fundamentally important information on the IFE based mechanism for the detection of various analytes.en
dc.description.statementofresponsibilityArvin Sain Tanwar, Sourabh Patidar, Saurabh Ahirwar, Sourav Dehingia and Parameswar Krishnan Iyeren
dc.language.isoenen
dc.publisherRoyal Society of Chemistryen
dc.rightsThis journal is © The Royal Society of Chemistry 2019en
dc.title"Receptor free" inner filter effect based universal sensors for nitroexplosive picric acid using two polyfluorene derivatives in the solution and solid statesen
dc.typeJournal articleen
dc.identifier.rmid0030105628en
dc.identifier.doi10.1039/c8an01970cen
dc.identifier.pubid452702-
pubs.library.collectionChemistry publicationsen
pubs.library.teamDS10en
pubs.verification-statusVerifieden
pubs.publication-statusPublisheden
dc.identifier.orcidAhirwar, S. [0000-0002-9422-4130]en
Appears in Collections:Media Studies publications

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.