Please use this identifier to cite or link to this item: https://hdl.handle.net/2440/2470
Citations
Scopus Web of Science® Altmetric
?
?
Type: Journal article
Title: Label-free bioaffinity detection using terahertz technology
Author: Mickan, S.
Menikh, A.
Liu, H.
Mannella, C.
MacColl, R.
Abbott, D.
Munch, J.
Zhang, X.
Citation: Physics in Medicine and Biology, 2002; 47(21):3789-3795
Publisher: IOP Publishing Ltd
Issue Date: 2002
ISSN: 0031-9155
1361-6560
Statement of
Responsibility: 
Samuel P Mickan, Abdellah Menikh, Haibo Liu, Carmen A Mannella, Robert MacColl, Derek Abbott, Jesper Munch and X-C Zhang
Abstract: We report the first use of differential terahertz time-domain spectroscopy for bioaffinity sensing. Binding is observed by measuring the transmission of a thin layer of biotin bound to the sensor protein avidin. We demonstrate the THz wave transmission of a sub-micron-thick film and sensitivity to 0.1 µg cm−2 of biotin. These results point the way for a host of biosensor applications using T-rays, or pulsed far-infrared (FIR) radiation.
Keywords: Macromolecular Substances
Avidin
Affinity Labels
Membranes, Artificial
Sensitivity and Specificity
Refractometry
Spectrum Analysis
Biosensing Techniques
Protein Binding
Biotin
Electromagnetic Phenomena
Surface Properties
Microwaves
Equipment Design
Description: © 2002 IOP Publishing
DOI: 10.1088/0031-9155/47/21/317
Published version: http://www.iop.org/EJ/abstract/0031-9155/47/21/317/
Appears in Collections:Aurora harvest 2
Electrical and Electronic Engineering publications
Environment Institute publications
Physics publications

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.