Please use this identifier to cite or link to this item: https://hdl.handle.net/2440/47557
Full metadata record
DC FieldValueLanguage
dc.contributor.authorJahangir, A.en
dc.contributor.authorLee, J. M.en
dc.contributor.authorWaldman, S. D.en
dc.contributor.authorAnderson, Gail Ireneen
dc.date.issued2002en
dc.identifier.citationBiomedical Sciences Instrumentation, 2002; 38:215-220en
dc.identifier.issn0067-8856en
dc.identifier.urihttp://hdl.handle.net/2440/47557-
dc.description.abstractMechanical loading alters cellular responses. While in vitro mechanical stimulation is a powerful tool for exploration of mechanotransduction, very little has been published documenting techniques for validation of such devices. We have developed an in vitro experimental system that imposes well-defined temporal and spatial strain profiles using a pressure-actuated, tethered diaphragm substrate (Bioflex dishes). More importantly we have accurately characterized the strain and strain rate performance of this system and herein describe that methodology. The prototype CSS deflected cell substrates over cylindrical platens, producing dynamic biaxial strains. Dynamic studies at 1 Hz were conducted at 8.0, 9.0, 10.0 and 13.0 kPa peak transmural pressures for a total of 1000 loading cycles. To study the effects of frequency, experiments were also run at 0.5 and 1.5 Hz at 8 and 13 kPa. A series of 33 dots were placed collinearly in rings on the membrane. Dot motions were monitored via a CCD video camera and acquisition was performed using an 8-bit gray-scale video board and N1H Image software. Strain fields and rates were subsequently calculated using Mathematica software. Results confirmed that the strains were biaxially uniform over the frequencies and pressures examined: e.g., at 9.0 KPa, max radial & circumferential strain = 0.009 +/- 0.001. It was also shown that, as transmural pressure was increased, both membrane strains and strain rates increased; however biaxial strain isotropy was preserved. While we cannot measure out-of-plane deflections, video-based image analysis is a very useful technique for validation of dynamic planar biaxial strains in cell stimulation systems.en
dc.description.urihttp://www.ncbi.nlm.nih.gov/pubmed/12085605en
dc.publisherElsevieren
dc.titleMechanical characterization of a novel cell stimulating system (CSS) to apply dynamic, uniform and isotropic biaxial strains to cells in vitroen
dc.typeJournal articleen
dc.contributor.schoolSchool of Animal and Veterinary Sciencesen
Appears in Collections:Animal and Veterinary Sciences publications

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.