Please use this identifier to cite or link to this item: https://hdl.handle.net/2440/58071
Full metadata record
DC FieldValueLanguage
dc.contributor.authorMou, Y.-
dc.contributor.authorChen, Y.-
dc.contributor.authorSmales, R.-
dc.contributor.authorYip, K.-
dc.date.issued2009-
dc.identifier.citationAmerican Journal of Dentistry, 2009; 22(5):311-314-
dc.identifier.issn0894-8275-
dc.identifier.urihttp://hdl.handle.net/2440/58071-
dc.description.abstractPURPOSE: To investigate the optimum diameter for the tapered post of a cast alloy post-core system relative to the root diameter, when measured at the root face, that is required to minimize both post and root failures. METHODS: 32 extracted maxillary central incisor teeth were each decoronated perpendicular to the long axis at a point 2.0 mm occlusal to the labial cemento-enamel junction. Following endodontic canal obturation, the teeth were assigned randomly to four equal groups for different diameter tapered post space preparations. Then 1.10, 1.50, 1.70, and 2.00 mm diameter cast Ni-Cr alloy post-cores and complete crowns without ferrules were fabricated. Each root was embedded in a large gypsum stone block and the crown loaded palatally at 135 degrees from the long axis in a universal testing machine at a crosshead speed of 1.0 mm/minute until failure. Results were analyzed using one-way ANOVA with Tukey-Kramer post hoc tests, and Fisher's exact test, with alpha = 0.05 for statistical significance. RESULTS: Mean failure resistance loads were: 0.60, 0.91, 1.00, and 1.38 kN (P < 0.001). All of the 1.10 mm posts failed, without any root fractures. Conversely, none of the 2.00 mm posts failed, but all of the roots fractured. The optimum post to root diameter ratio to minimize failures was approximately 1:4.-
dc.description.statementofresponsibilityYong-Bin Mou, Ya-Ming Chen, Roger J Smales and Kevin H K Yip-
dc.description.urihttp://www.researchgate.net/publication/41940997-
dc.language.isoen-
dc.publisherMosher & Linder Inc-
dc.rightsCopyright status unknown-
dc.subjectDental Pulp Cavity-
dc.subjectDentin-
dc.subjectTooth Root-
dc.subjectHumans-
dc.subjectTooth Fractures-
dc.subjectChromium Alloys-
dc.subjectDental Casting Investment-
dc.subjectOdontometry-
dc.subjectMaterials Testing-
dc.subjectDental Stress Analysis-
dc.subjectDental Restoration Failure-
dc.subjectCrowns-
dc.subjectPost and Core Technique-
dc.subjectRoot Canal Preparation-
dc.subjectDental Prosthesis Design-
dc.subjectSurface Properties-
dc.subjectStress, Mechanical-
dc.subjectAged-
dc.subjectMiddle Aged-
dc.titleOptimum post and tooth root diameters for a cast post-core system-
dc.typeJournal article-
pubs.publication-statusPublished-
Appears in Collections:Aurora harvest
Dentistry publications

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.