Please use this identifier to cite or link to this item: https://hdl.handle.net/2440/58473
Type: Journal article
Title: Evaluation of a bedside technique for post-pyloric placement of feeding catheters
Author: Deane, A.
Fraser, R.
Young, R.
Foreman, B.
O'Conner, S.
Chapman, M.
Citation: Critical Care and Resuscitation, 2009; 11(3):180-183
Publisher: Australasian Academy of Critical Care Medicine
Issue Date: 2009
ISSN: 1441-2772
2652-9335
Statement of
Responsibility: 
Adam M Deane, Robert J Fraser, Robert J Young,Benita Foreman, Stephanie N O’Conner and Marianne J Chapman
Abstract: Objectives: To establish the success rate, time taken and expertise required to place a feeding catheter into the small intestine using a device that permits real-time localisation of the catheter through detection of an electromagnetic field. Design: Prospective observational study. Setting: A tertiary, mixed medical–surgical, adult intensive care unit, between February 2008 and February 2009. Participants: 60 attempts at postpyloric intubation by eight clinicians (consultant and trainee intensivists and a dietitian) in 57 critically ill patients who were undergoing mechanical ventilation and were receiving, or suitable to receive, enteral nutrition. Main outcome measures: Patients were classified into an initial group (10 patients), who had the catheter placed by a single clinician to establish the most effective technique, and a subsequent group (50 patients), who had the catheter placed by any of the eight clinicians. Catheter position was confirmed on abdominal x-ray by an independent radiologist. Results: Postpyloric catheter placement was successful in 56/60 attempts (93%), in 54/57 patients (95%), with a median time to placement of 7.2min (interquartile range [IQR], 4.3–12.5min). In the initial group, placement was successful in 7/10 attempts (70%), with a median time to placement of 20.8min (IQR, 9.5–32.3 min), compared with 49/50 attempts (98%) and a median time of 5.9 min (IQR, 3.9–11.9min) in the subsequent group (P = 0.003). Conclusions: An electromagnetically guided device enabled reliable and rapid bedside placement of small-intestinal feeding catheters. Proficiency with the technique was quickly developed and successfully disseminated to a range of clinicians.
Keywords: Intestine, Small
Humans
Critical Illness
Radiography, Abdominal
Catheterization, Peripheral
Enteral Nutrition
Follow-Up Studies
Prospective Studies
Equipment Design
Adult
Aged
Middle Aged
Point-of-Care Systems
Female
Male
Rights: Copyright status unknown
Description (link): http://search.informit.com.au/documentSummary;dn=796137630287605;res=IELHEA
Appears in Collections:Aurora harvest
Medicine publications

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.