Please use this identifier to cite or link to this item: https://hdl.handle.net/2440/66477
Citations
Scopus Web of Science® Altmetric
?
?
Full metadata record
DC FieldValueLanguage
dc.contributor.authorSallustio, B.-
dc.contributor.authorNoll, B.-
dc.contributor.authorMorris, R.-
dc.date.issued2011-
dc.identifier.citationClinical Biochemistry, 2011; 44(2-3):231-236-
dc.identifier.issn0009-9120-
dc.identifier.issn1873-2933-
dc.identifier.urihttp://hdl.handle.net/2440/66477-
dc.description.abstract<h4>Objectives</h4>An LC-MS/MS method was developed for simultaneous quantitation of tacrolimus, sirolimus and everolimus in whole blood, and compared to HPLC-UV and immunoassay methods.<h4>Design and methods</h4>Blood (0.1mL) was analysed following solid-phase extraction and chromatographic resolution using a C18 column (45°C) and mobile phase of methanol/40mM ammonium acetate/glacial acetic acid (83/17/0.1) at 200μL/min, with positive electrospray ionisation and multiple reaction monitoring.<h4>Results</h4>Intra- and inter-day imprecision and inaccuracy were ≤12.2% over a 1.5-40μg/L calibration range. An external quality assurance programme confirmed acceptable inaccuracy and imprecision of the LC-MS/MS method, but highlighted problems with immunoassay quantitation, particularly for everolimus, showing a >30% bias in FPIA everolimus concentrations measured in pooled patient samples versus spiked drug-free whole blood.<h4>Conclusions</h4>LC-MS/MS provides significant accuracy and precision advantages compared to HPLC and immunoassays. Discrepancies in everolimus concentrations measured by the Seradyn FPIA immunoassay require further investigation.-
dc.description.statementofresponsibilityBenedetta C. Sallustio, Benjamin D. Noll, Raymond G. Morris-
dc.language.isoen-
dc.publisherPergamon-Elsevier Science Ltd-
dc.rightsCrown copyright © 2010 Published by Elsevier Inc. All rights reserved.-
dc.source.urihttp://dx.doi.org/10.1016/j.clinbiochem.2010.10.005-
dc.subjectLC-MS/MS-
dc.subjectImmunoassays-
dc.subjectSirolimus-
dc.subjectTacrolimus-
dc.subjectEverolimus-
dc.titleComparison of blood sirolimus, tacrolimus and everolimus concentrations measured by LC-MS/MS, HPLC-UV and immunoassay methods-
dc.typeJournal article-
dc.identifier.doi10.1016/j.clinbiochem.2010.10.005-
pubs.publication-statusPublished-
dc.identifier.orcidSallustio, B. [0000-0002-0186-3073]-
Appears in Collections:Aurora harvest 5
Pharmacology publications

Files in This Item:
File Description SizeFormat 
hdl_66477.pdfAccepted version1.26 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.