Please use this identifier to cite or link to this item:
https://hdl.handle.net/2440/67052
Citations | ||
Scopus | Web of Science® | Altmetric |
---|---|---|
?
|
?
|
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Bartold, P. | - |
dc.contributor.author | Kuliwaba, J. | - |
dc.contributor.author | Lee, V. | - |
dc.contributor.author | Shah, S. | - |
dc.contributor.author | Marino, V. | - |
dc.contributor.author | Fazzalari, N. | - |
dc.date.issued | 2011 | - |
dc.identifier.citation | Clinical Oral Implants Research, 2011; 22(6):613-618 | - |
dc.identifier.issn | 0905-7161 | - |
dc.identifier.issn | 1600-0501 | - |
dc.identifier.uri | http://hdl.handle.net/2440/67052 | - |
dc.description.abstract | Objectives: To assess the relationship between smooth and roughened implant surfaces of straight and narrow configurations with respect to microdamage of the bone surface during placement of dental implants Materials and methods: Straight and tapered, rough and smooth surface Nobel Biocare implants were placed into sheep mandibles. Microdamage within the bone adjacent to the implant surface was quantitated using a semi-automated digitized histomorphometric method. Results: Independent of implant type, microdamage, microcracks, cross-hatch damage and diffuse damage were significantly higher close to the implants compared with far from the implants. Microcracks and cross-hatch damage were higher for the rough cylindrical implants than all the other implant types. Conclusions: Insertion of a rough cylindrical implant type results in an increased fraction of microdamaged bone matrix in comparison to rough tapered, smooth cylindrical and smooth tapered implants. | - |
dc.description.statementofresponsibility | P. M. Bartold, J. S. Kuliwaba, V. Lee, S. Shah, V. Marino, N. L. Fazzalari | - |
dc.language.iso | en | - |
dc.publisher | Munksgaard Int Publ Ltd | - |
dc.rights | © 2010 John Wiley & Sons A/S | - |
dc.source.uri | http://dx.doi.org/10.1111/j.1600-0501.2010.02024.x | - |
dc.subject | implant shape | - |
dc.subject | implant surface | - |
dc.subject | microdamage | - |
dc.title | Influence of surface roughness and shape on microdamage of the osseous surface adjacent to titanium dental implants | - |
dc.type | Journal article | - |
dc.identifier.doi | 10.1111/j.1600-0501.2010.02024.x | - |
pubs.publication-status | Published | - |
dc.identifier.orcid | Bartold, P. [0000-0002-5695-3877] | - |
dc.identifier.orcid | Kuliwaba, J. [0000-0003-1942-9299] | - |
Appears in Collections: | Aurora harvest 5 Dentistry publications |
Files in This Item:
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.