Please use this identifier to cite or link to this item: https://hdl.handle.net/2440/99828
Citations
Scopus Web of Science® Altmetric
?
?
Type: Journal article
Title: "Turn-of-the-nut" method is not appropriate for use in cancellous bone
Author: Ryan, M.
Mohtar, A.
Costi, J.
Reynolds, K.
Citation: Journal of Orthopaedic Trauma, 2015; 29(11):e437-e441
Publisher: Lippincott, Williams & Wilkins
Issue Date: 2015
ISSN: 1531-2291
1531-2291
Statement of
Responsibility: 
Melissa K. Ryan, Aaron A. Mohtar, John J. Costi and Karen J. Reynolds
Abstract: Objective: The level to which bone screws are tightened is determined subjectively by the operating surgeon. It is likely that the tactile feedback that surgeons rely on is based on localized tissue yielding, which may predispose the screw–bone interface to failure. A limited number of studies have investigated the ratio between clinical tightening torque and stripping torque. The purpose of this study was to measure, for the first time, the ratio between yield torque (Tyield) and stripping torque (Tmax) during screw insertion into the cancellous bone and to compare these torques with clinical levels of tightening reported in the literature. Additionally, a rotational limit was investigated as a potential end point for screw insertion in cancellous bone. Methods: A 6.5-mm outer diameter commercial cancellous bone screw was inserted into human femoral head specimens (n = 89). Screws were inserted to failure, while recording insertion torque, compression under the screw head, and rotation angle. Results: The median, interquartile ranges, and coefficient of variation were calculated for each of the following parameters: Tyield, Tmax, Tyield/Tmax, slope, Tplateau, and rotation angle. The median ratio of Tyield/Tmax and rotation angle was 85.45% and 96.5 degrees, respectively. The coefficient of variation was greatest for the rotation angle compared with the ratio of Tyield/Tmax (0.37 vs. 0.12). Conclusions: The detection of yield may be a more precise method than the rotation angle in cancellous bone; however, bone–screw constructs that exhibit a Tyield close to Tmax may be more susceptible to stripping during insertion. Future work can identify factors that influence the ratio of Tyield/Tmax may help to reduce the incidence of screw stripping.
Keywords: Insertion torque; yield torque; stripping torque; screw stripping; cancellous bone
Rights: Copyright © 2015 Wolters Kluwer Health, Inc. All rights reserved.
DOI: 10.1097/BOT.0000000000000385
Grant ID: http://purl.org/au-research/grants/nhmrc/595933
Published version: http://dx.doi.org/10.1097/bot.0000000000000385
Appears in Collections:Aurora harvest 3
Mechanical Engineering publications

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.